saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 4554 > < Initial Inspection and Diagnostic Overview|Page 4552
Page 47
background image

YES -

Continue with Checking the Trionic Control Module Power Supply and Ground Connection

-

Connect test lamp 86 11 857 between pin 1 of the female connector and a good grounding point.

-

The test lamp should light.

Checking the wiring harness.

Jiggle the leads and in-line connectors at several places and in different directions to reveal intermittent breaks and short circuits in the wiring harness.
Observe the multimeter, test lamp or diagnostic tool while doing this.

Is the function correct?

NO

-

See: No Communication With the Trionic T5/Rectifying the Lead - III 

YES -

Continue with Checking the Trionic Control Module Power Supply and Ground Connection

-

Connect test lamp 86 11 857 between pin 1 on the control module female connector and pin 25.

-

The test lamp should light.

Checking the wiring harness.

Jiggle the leads and in-line connectors at several places and in different directions to reveal intermittent breaks and short circuits in the wiring harness.
Observe the multimeter, test lamp or diagnostic tool while doing this.

Initial Inspection and Diagnostic Overview|Page 4554 > < Initial Inspection and Diagnostic Overview|Page 4552