saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 4564 > < Initial Inspection and Diagnostic Overview|Page 4562
Page 57
background image

NO

-

See: No Contact With Any Bus System/Rectifying the Lead - II 

YES -

See: No Contact With Any Bus System/Check DICE Control Module's Current Supply (+15 Circuit) 

Check That the DICE Control Module Is Awake

Check That the DICE Control Module Is Awake

-

Turn the ignition switch to the ON position.

-

Start the windscreen wipers, select INTERMITTENT OPERATION.

Intermittent wiper operation should work.

Is the function correct?

NO

-

See: No Contact With Any Bus System/Checking the DICE Control Module's Current Supply (+30 Circuit) 

YES -

See: No Contact With Any Bus System/Checking the Diagnostic Tool - I 

Check That the DICE Control Module's Grounding

Check That the DICE Control Module's Grounding

-

Connect test lamp 86 11 857 to pins 26 and 57 of the control module's female connector.

-

The test lamp should light.

Checking the wiring harness.

Jiggle the leads and in-line connectors at several places and in different directions to reveal intermittent breaks and short circuits in the wiring harness.
Observe the multimeter, test lamp or diagnostic tool while doing this.

Is the function correct?

NO

-

See: No Contact With Any Bus System/Rectifying the Lead - II 

YES -

Continue with Checking the DICE control module's grounding.

Initial Inspection and Diagnostic Overview|Page 4564 > < Initial Inspection and Diagnostic Overview|Page 4562