saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 3225 > < Initial Inspection and Diagnostic Overview|Page 3223
Page 11
background image

1. Make sure there is no power being supplied to the lead to be checked (e.g. by removing the relevant fuse) and that any loads have been

disconnected.

2. Set the multimeter till ohm measurement.
3. Connect one test lead to a reliable ground and the other to the point to be checked.
4. Carefully jiggle the wiring harness and check that the multimeter shows a constant infinite value (OL).

Initial Inspection and Diagnostic Overview|Page 3225 > < Initial Inspection and Diagnostic Overview|Page 3223