saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

Symptom Related Diagnostic Procedures|Page 9626 > < Symptom Related Diagnostic Procedures|Page 9624
Page 3
background image

Pin No. 18 - 26

Test Values and Control Module Connections For Popular

Scope

Values and instructions for testing the voltage levels of the control modules are found under the relevant headed sections.

Remember:

-

Observe the conditions set for testing and use common sense when assessing the results.

-

The test values presented apply when the ignition is in the ON position unless otherwise stated.

-

First make sure that the control module is receiving power and that it is grounded.

-

Then check all the sensor inputs and signals from other systems.

-

Finally, check the control module outputs. Remember that the test values do not indicate whether the module is working.

-

If a test value is incorrect, consult the wiring diagram to trace which leads, connectors and components should be checked more thoroughly.

-

The specified test values refer to those obtained with calibrated Fluke 88/97.

-

Test values in % (+) and ms (+) show the pulse ratio and pulse duration of the signal. A test instrument capable of giving pulse ratio and pulse
duration readings should be used. The (+) symbol indicates a positive trigger pulse TRIG+.