9-5 Linear (9600) L4-2.3L Turbo (2.3t) (2004)
Pin No. 69-70
DICE Control Module (628)
Test Readings, Control Module Connections
Scope
Readings and directions for measuring control module voltage levels can be found under this heading.
Remember:
^
Note the test conditions and use common sense when assessing the test result.
^
The specified readings are with the ignition in position ON unless otherwise stated.
^
First check that the control module has a power supply and is grounded.
^
Then check all sensor inputs and signals from other systems.
^
Finally, check the control module outputs. Remember that the readings do not determine whether the actuator is working.
^
If any reading is not OK, consult the wiring diagram to trace the leads, connectors or components which should be checked more thoroughly.
^
The specified test readings refer to those obtained with a calibrated Fluke 88/97.
^
Test readings in % (+) and ms (+) show the pulse ratio and pulse duration of the signal. A test instrument capable of giving pulse ratio and pulse