9-5 SE Wagon (9600) V6-3.0L Turbo (B308) (2001)
The function gives the CHECK message on the SID display (70 second delay). See: Check Messages
Diagnostics
If the circuit to the washer fluid level sensor is broken, the text message "WASHER FLUID LEVEL LOW" will be shown despite a correct washer fluid
level.
If a short-circuit to ground occurs, the CHECK message will not be shown even if the washer fluid level is low.
The SID will not generate a diagnostic trouble code.
Filament Monitor, Front Lights
Filament Monitor, Front Lights