Air Door Actuator / Motor: Service and Repair
Defroster Valve Actuator Replacement
Defroster Valve Actuator Replacement
Removal Procedure
1. Remove the instrument panel (I/P) carrier. Refer to Instrument Panel Carrier Replacement (See: Body and Frame/Interior Moulding /
Trim/Dashboard / Instrument Panel/Service and Repair/Instrument Panel Carrier Replacement).
2. Disconnect the electrical connector from the defroster actuator.
3. Remove the screws from the defroster actuator.
4. Remove the defroster actuator.
Installation Procedure
1. Install the defroster actuator.
Notice: Refer to Fastener Notice.
2. Install the defroster actuator screws.
Tighten the screws to 1.9 Nm (17 in. lbs.).
3. Connect the electrical connector to the defroster actuator.
4. Install the I/P carrier. Refer to Instrument Panel Carrier Replacement (See: Body and Frame/Interior Moulding / Trim/Dashboard / Instrument
Panel/Service and Repair/Instrument Panel Carrier Replacement).