900 L4-2118cc 2.1L DOHC (1992)
![background image](/saab/900/l4-2118cc_2.1l_dohc/Page-1028001.png)
Auxiliary Blower Motor: Description and Operation
AC Radiator Fan 172
Extra radiator fan 172 for the AC is connected via relay 155 and is supplied from fuse 6.
The relay coil is supplied from the contacts of relay 156 and from pressure switch 166. The AC radiator fan thus runs when AC switch 169 is depressed
and pressure switch 166 is closed.