saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

EDU System Description|Page 6256 > < EDU System Description|Page 6254
Page 24
background image

which feeds out a voltage on pin 30 in the range 1 - 9 V depending on the temperature display. The function of the temperature display is the same as the
fuel level gauge display.

If the resistance in the resistor is under 66 Ohms or over 100 kOhms, a diagnostic trouble code is generated in the control module and the control
module starts the radiator fan until the fault is remedied.

Radiator Fan, Low Speed and High Speed

The car may be equipped with either a 1 step or a 2 step radiator fan.

The speed of the 1 step fan is somewhere between step 1 and step 2 of the 2 step fan.

EDU System Description|Page 6256 > < EDU System Description|Page 6254