saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

Symptom Related Diagnostic Procedures|Page 6300 > < Symptom Related Diagnostic Procedures|Page 6298
Page 28
background image

Action

1

Connect the Intelligent Saab Tester (ISAT) and activate "ENGINE TEMP GAUGE and check that the values programmed in ° C in the ISAT
correspond with the temperature gauge display.
Unplug the connector from the back of the temperature gauge. Measure the voltage on pin 7 of the temperature gauge. This should be between 1
and 9 V
 depending on the engine temperature. 
If there is voltage, change the instrument.
If there is no voltage, check the cable assembly between pin 7 on the instrument and pin 30 on the Electronic Display Unit (EDU) control module
for open/short circuit. 
If the fault remains, proceed to "Action Before Changing A Control Module".

2

Unplug the connector from the back of the temperature gauge. Measure the voltage between pin 2 and ground. Should be about 1 V under battery
positive voltage.
If there is voltage, change the temperature gauge.
If there is no voltage, check the cable assembly between control module pin 22 and temperature gauge pin 2 for open/short circuit.
If the fault remains, proceed to "Action Before Changing A Control Module".

3

Check the lead between temperature gauge pin 5 and grounding point G8 for open circuit. Localize and remedy the fault.
If the fault remains, change the fuel gauge.

Preliminary Information

Scope

On the following pages are listed values and instructions for measuring signals/levels in the Electronic Display Unit (EDU) control module.

Remember:

Symptom Related Diagnostic Procedures|Page 6300 > < Symptom Related Diagnostic Procedures|Page 6298