saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 1879 > < Diagram Information and Instructions|Page 1877
Page 4
background image

419

A/C cooling pressure switch (ME), under the radiator on the right- hand side.

433

Relay for disengagement of radiator fan, in main fuse box in front of battery.

2-Pin Connectors

H2-4

Adjacent to the radiator fan motor.

H2-85

Adjacent to the radiator fan motor.

 

3-Pin Connector

H3-23

Under the front bumper behind the right-hand fog light.

4-Pin Connector

H4-12

Beside the right-hand wheel housing adjacent to the receiver.

10-Pin Connectors

H10-15

Behind the left-hand headlamp. 

H10-25

Behind the left-hand headlamp.

Grounding  Points

G30

Grounding point on the left-hand structural member, behind the left-hand headlamp.

G31

Grounding point on the right-hand structural member, behind the right-hand headlamp.

DESCRIPTION OF OPERATION

The cooling fans are controlled from the EDU control module.

Irrespective of the position of the ignition switch, power is supplied to relay 155 via fuse 4.

The engine coolant temperature is measured by the EDU control module, which controls relay 155.

Single-Speed Radiator Fan 37
When coolant temperature reaches about 100°C (212°F), relay 155 operates and radiator fan 37 starts. When the temperature drops to about 96°C
(205°F)
, the fan stops.

2-Speed Radiator Tan 366
Some cars are fitted with a 2-speed radiator fan which gives efficient cooling.

Speed 1 works as above.

When the coolant temperature reaches 111°C (232°F), relay 81 is grounded via the EDU control module. The radiator fan then runs at full speed.
When the coolant temperature drops to 107°C (225°F), the fan reverts to speed 1.

Relay, Disengagement Of Radiator Fan 433
To prevent the battery from being drained when the radiator fan continues to run after the engine has been switched off, relay 433 breaks the
circuit as soon as the ignition is switched off. However, the EDU control module can cause relay 155 to operate so that the fan will continue to run
at speed 1, but then only for 3.5 minutes.

Extra Pressure Switch 419
In certain markets, the A/C system is equipped with an extra pressure switch which controls relay 81. If the refrigerant pressure exceeds 22 bar, the
contact is closed. This activates relay 81 and engages speed 2 on radiator fan 366.

FAULT DIAGNOSIS HINTS

1-Speed Radiator Fan
1. Check that fuse 4 is intact and live.
2. Check that current is supplied to relay 155.
3. Check that the relay operates and that the radiator fan is working.
4. Run the engine until it reaches operating temperature and check that the EDU control module is in working order.
5. Check connectors and the wiring harness as well as ground connections.

2-Speed Radiator Fan
1. Check that fuse 4 is intact and live.
2. Inspect maxi fuse 2.
3. Check fuse 3.

Diagram Information and Instructions|Page 1879 > < Diagram Information and Instructions|Page 1877