9000 CSE V6-2962cc 3.0L DOHC (B308) (1996)
![background image](/saab/9000_cse/v6-2962cc_3.0l_dohc_(b308)/Page-1906026.png)
Radiator fan step 2 not working.
Action
1
Check that max fuse 2 in the engine compartment electrical distribution box is intact.
2
Remove relays and check the voltage supply to pin 1 (relay 30). This should be battery positive voltage.
If not, check the cable assembly for open/short circuit to ground.
3
Bridge between pin I and pin 2 in the relay bracket (relays 30-87). The radiator fan should now start. If not, check the cable assembly and
connectors to the radiator fan motor and grounding leads with connectors from the radiator fan motor.
4
Install the relays.
5
Connect the Intelligent Saab Tester (ISAT) and activate "RADIATOR FAN HIGH".
ON = radiator fan activated
OFF = not activated
If the radiator fan does not work when activated, change relays.
If the fault remains, proceed to "Action Before Changing A Control Module".
Engine Temperature Display