On Harrison evaporators, the cooling plate on which the fan control unit is mounted is welded to the evaporator.

An aluminium spacer (supplied together with the fan control module) must be fitted between the fan control unit and the cooling plate.

Important

Wipe away old silicon paste from the mounting surface on the evaporator.

Apply a thin coat of silicon paste, part no. 30 07 695 (CA: 1974984) on the metal plate on the fan control unit and the mounting surface on the
evaporator. This is important for the function and service life.

Place the aluminium spacer on the fan control unit. Turn the spacer so that it is lying edge to edge with the side of the fan control unit, see illustration.
Make sure the two sleeves on the fan control unit fit into the holes in the aluminium spacer.

Screw the tan control unit to the evaporator. Plug in the connector.

Check the fitting and replace all removed parts, see "8. Climate control, Adjustment/replacement, Fan control unit".