2. Disconnect the wiring harness plugs.

3. Remove the recirculation actuator (1).

*

Remove the 3 bolts.

*

Disconnect the wiring harness plug (2).

*

Release and disconnect the wiring harness plug.

Installation Procedure

Caution:  Refer to Fastener Caution   (See: Service Precautions/Vehicle Damage Warnings/Fastener Caution).

Note:  The recirculation actuator can only be fitted in one position and is self-calibrating.

1. Install the recirculation actuator.

Tighten the 3 bolts to 5 Nm (44 lb in).

2. Connect the wiring harness plug.
3. Install the I/P compartment.
4. Connect the wiring harness plug.

Tighten 4 bolts to 4 Nm (35 lb in).

Note:  Only upon replacement of air inlet actuator.

5. Connect the battery.
6. For programming procedures, refer to Control Module References   (See: Testing and Inspection/Programming and Relearning).
7. Perform the function inspection.