saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 13132 > < Diagram Information and Instructions|Page 13130
Page 2
background image

‹› If the rear window defogger does not turn ON and OFF when changing between the commanded states, refer to Rear Window Defogger

Malfunction.

3. Command the Rear Window Defog LED Test ON and OFF with a scan tool. The rear window defogger indicator should turn ON and OFF when

changing between the commanded states.

‹› If the rear window defogger indicator does not illuminate or continuously illuminates, refer to Rear Window Defogger Indicator Malfunction.

Circuit/System Testing

Rear Window Defogger Switch Malfunction

1. Ignition OFF, disconnect the X1 harness connector at the HVAC control module.
2. Ignition ON, verify the scan tool Defrost Switch parameter is Inactive.

‹› If not the specified value, test the signal circuit terminal 12 for a short to voltage. If the circuit tests normal, replace the IPC.

3. Connect a 5A fused jumper wire between the signal circuit terminal 12 and B+. Verify the scan tool Defrost Switch parameter is Active.

‹› If not the specified value, test the signal circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the IPC.

4. If all circuits test normal, replace the HVAC control module.

Rear Window Defogger Malfunction

1. Ignition OFF, disconnect the K2 relay.
2. Ignition ON, verify a test lamp does not illuminate between the control circuit terminal 87 and ground.

‹› If the test lamp illuminates, test the control circuit for a short to voltage.

3. Verify a test lamp illuminates between the B+ circuit terminal 86 and ground.

‹› If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance.

4. Verify a test lamp illuminates between the B+ circuit terminal 30 and ground.

‹› If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance.

5. Disconnect the X2 harness connector at the rear window defogger grid.
6. Ignition OFF, test for less than 1 ohm between the ground circuit terminal 1 and ground.

‹› If greater than the specified range, test the ground circuit for an open/high resistance.

7. Connect the harness connector at the rear window defogger grid.
8. Ignition ON, connect a 15A fused jumper wire between the B+ circuit terminal 30 and the control circuit terminal 87. Verify the rear window

defogger grid is activated.

‹› If the rear window defogger grid does not activate, test the control circuit for a short to ground or an open/high resistance. If the circuit tests

normal, test or replace the rear window defogger grid.

9. Connect a test lamp between the B+ circuit terminal 86 and the control circuit terminal 85.

10. Command the REC Heated Rear Window Test ON and OFF with a scan tool. The test lamp should turn ON and OFF when changing between the

commanded states.

‹› If the test lamp is always ON, replace the rear fuse block.
‹› If the test lamp is always OFF, replace the rear fuse block.

11. If all circuits test normal, test or replace the K2 relay.

Rear Window Defogger Indicator Malfunction

1. Ignition OFF, disconnect the harness connector at the HVAC control module.
2. Ignition ON, command the Rear Window Defog LED Test OFF with a scan tool
3. Test for less than 1 volt between the control circuit terminal 13 and ground.

‹› If greater than the specified range, test the control circuit for a short to voltage. If the circuit tests normal, replace the IPC.

4. Command the Rear Window Defog LED Test ON with a scan tool.

Diagram Information and Instructions|Page 13132 > < Diagram Information and Instructions|Page 13130