Aura L4-2.4L (2008)
Canister Purge Solenoid: Service and Repair
Evaporative Emission Canister Purge Solenoid Valve Replacement
Removal Procedure
1. Remove the intake manifold cover. Refer to Intake Manifold Cover Replacement (See: Engine, Cooling and Exhaust/Engine/Intake
Manifold/Service and Repair).
2. Remove the air cleaner outlet duct. Refer to Air Cleaner Outlet Duct Replacement (1st Design) (See: Fuel Delivery and Air Induction/Air Cleaner
Housing/Air Cleaner Fresh Air Duct/Hose/Service and Repair/Air Cleaner Outlet Duct Replacement (1st Design))Air Cleaner Outlet Duct
Replacement (2nd Design) (See: Fuel Delivery and Air Induction/Air Cleaner Housing/Air Cleaner Fresh Air Duct/Hose/Service and Repair/Air
Cleaner Outlet Duct Replacement (2nd Design)).
3. Remove the generator battery control module cover, if necessary. Refer to Generator Control Module Cover Replacement ().
4. Disconnect the engine wiring harness electrical connector (1) from the evaporative emission (EVAP) canister purge solenoid valve (2).
5. Disconnect the chassis EVAP line quick connect fitting (2) from the EVAP canister purge solenoid valve. Refer to Plastic Collar Quick Connect