Page 3
background image

4. Remove the plugs from the proportioning valve assembly ports.
5. Remove the caps or plugs from the master cylinder brake pipe ends.
6. Connect the master cylinder brake pipes (2) to the proportioning valve assembly.
7. Tighten the brake pipe fittings at the proportioning valve assembly.

First Design ISO Flare to 19 Nm (14 ft. lbs.)
Second Design Double Inverted Flare to 18 Nm (13 ft. lbs.)

8. Remove the caps or plugs from the caliper and wheel cylinder brake pipe ends.
9. Connect the caliper and wheel cylinder brake pipes (1) to the proportioning valve assembly.

10. Tighten the brake pipe fittings at the proportioning valve assembly.

First Design ISO Flare to 19 Nm (14 ft. lbs.)
Second Design Double Inverted Flare to 18 Nm (13 ft. lbs.)

11. Bleed the hydraulic brake system. 
12. Remove the shop towel and discard into an approved container.