saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Coolant Reservoir|Service and Repair|Page 2931 > < Coolant Reservoir|Service and Repair|Page 2929
Page 3
background image

3. With the surge tank raised, install the surge tank outlet hose.
4. Reposition the hose clamp using SA91 11 E to secure the hose.

Notice:  Refer to Fastener Notice in Service Precautions.

5. Install the surge tank bolt.

^

Tighten the bolt to 8 Nm (70 inch lbs.).

6. Set the underhood junction block bracket into position.
7. Install the underhood junction block bracket nuts (1,2). 

^

Tighten the nuts to 10 Nm (88 inch lbs.).

8. Install the underhood junction block bracket bolt (3). 

^

Tighten the bolt to 25 Nm (18 ft. lbs.)

9. Install the surge tank inlet hose to the surge tank.

10. Reposition the hose clamp to secure the hose.

Coolant Reservoir|Service and Repair|Page 2931 > < Coolant Reservoir|Service and Repair|Page 2929