saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Canister Purge Solenoid|Locations|Page 4205 > < Canister Purge Solenoid|Locations|Page 4203
Page 1
background image

Canister Purge Solenoid: Service and Repair

EVAPORATIVE EMISSION (EVAP) CANISTER PURGE SOLENOID VALVE REPLACEMENT

REMOVAL PROCEDURE

1. Disconnect the evaporative emission (EVAP) canister purge valve harness connector.
2. Disconnect the vacuum pipe from the EVAP canister purge valve.
3. Disconnect the purge pipe from the EVAP canister purge valve.

4. Remove the EVAP canister purge valve and bracket.
5. Remove the EVAP canister purge valve from the purge bracket.
6. Inspect for carbon release in the EVAP canister purge valve ports. Refer to Evaporative Emission (EVAP) System Cleaning.

INSTALLATION PROCEDURE

1. Install the EVAP canister purge valve on to the purge bracket.

NOTE:  Refer to Fastener Notice in Service Precautions.