saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Restraint Systems > < Service Port Valves|Page 9169
Page 1
background image

Service Port HVAC: Service and Repair
Valve Core - High Side

REMOVAL

1. Discharge refrigerant system using an approved refrigerant recovery system.
2. Using a back-up wrench to support service port base, use second wrench to remove valve assembly.

INSTALLATION

1. Lubricate valve assembly O-ring with mineral oil.
2. Thread valve assembly into service port base and tighten.

Torque:
Valve Assembly-to-Service Port Base Fastener: 12 N.m (106 in-lbs)

3. Evacuate, charge, and leak test A/C system.

NOTE:  To prevent loss of refrigerant charge, make sure to install and tighten cap. Replace cap if seal is missing or damaged.

Restraint Systems > < Service Port Valves|Page 9169