saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Information Bus > < Diagram Information and Instructions|Page 4219
Page 2
background image

1. Measure distance between tip of IAC valve and IAC valve mounting flange as shown in illustration.
2. If measurement is greater than 28 mm (1.10 in), use finger pressure to slowly retract pintle until the distance becomes at least less than 20 mm (

0.79 in). The force required retracting the pintle of a new IAC valve will not damage the worm drive.

INSTALLATION  

1. Lubricate IAC valve O-ring with clean engine oil.
2. Install IAC valve with O-ring by installing assembly slightly counterclockwise from attachment screw holes.
3. Twist assembly clockwise until IAC valve is seated properly and aligned with attachment screw holes.
4. Install IAC valve attachment screws.

Torque:
IAC Valve Screws: 3 N.m (27 in-lbs)

5. Connect IAC valve harness connector. Push in connector until a click is heard, then pull back to confirm a positive engagement.
6. Perform the following procedure, which will allow the PCM to relearn the IAC valve position.

6.1 Turn ignition On with engine Off for 10 seconds; then turn ignition Off for 10 seconds.
6.2 Start engine and let idle for 30 seconds.
6.3 Accelerate engine slowly between idle and 3500 rpm five times.
6.4 Let engine return to idle. IAC valve position should be relearned.

Information Bus > < Diagram Information and Instructions|Page 4219