9. Remove four filter housing attachment bolts and remove filter housing.

10. Remove four blower motor housing screws, release locking tabs and remove fan housing.
11. Disconnect blower motor electrical connector by squeezing bottom of connector and pulling downward.
12. Remove blower motor assembly by lifting straight out.

IMPORTANT:  On earlier vehicles a bolt was used instead of a stud/nut.

13. Hand tighten suction/liquid line assembly to TXV stud into TXV. The stud will be used to aid installation.

Expansion Valve|Locations|Page 9957 > < Expansion Valve|Locations|Page 9955