saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Bench Overhaul|Page 10036 > < Bench Overhaul|Page 10034
Page 4
background image

15. Install recirculation actuator assembly onto door shaft. Shaft has two flats that must be aligned to actuator. Install recirculation actuator bracket to

module screws.

Torque:
Recirculation Actuator Bracket-to-HVAC Module Screws: 1.0 N.m (9 in-lbs)

16. Install vent and heater sub-levers. These sub-levers are identical and should have the slotted end inward.
17. Install defrost door to sub-lever.

Bench Overhaul|Page 10036 > < Bench Overhaul|Page 10034