5. Install protective caps on service ports and hand tighten.
6. Turn engine Off.
7. Leak check system with electronic leak detector or equivalent.
8. With system fully charged and leak-checked, conduct a functional and performance test (refer to diagnostic flow chart).

Refrigerant Drum Method

IMPORTANT:

^

Refer to the emissions certification label (Saturn Power Module) for proper amount of R-134a charge.

^

Verifying the purity of the refrigerant with a refrigerant purity identifier before charging is recommended.

If the R-134a drum is used, place it on a scale and note the total weight before charging. Watch the scale during charging to determine the amount of
R-134a used.

1. Connect the manifold gauge set as follows:

1.1 Low pressure gauge hose to low pressure service port on suction pipe muffler at inner right strut housing. Do not connect high pressure line to

the A/C system.

1.2 Manifold gauge set center hose connected to R-134a source.

Charging Station Method

Follow charging instructions provided with the charging station in use with the following exceptions:

1. Do not connect the high side service valve to the air conditioning system.
2. Keep the high pressure valve on the charging station closed at all times.
3. Perform the entire charge procedure through the low side pressure service port on the suction pipe.
4. Following these procedures will prevent accidental high side vehicle system pressure being subjected to the charging station in the event an error is

made in valve closing sequence during compressor operation to pull in the R-134a charge.

Refrigerant Oil > < Handling R-134A|Page 10118