Service Port HVAC: Service and Repair
Valve Core - Low Side

TOOLS REQUIRED

^

SA9149AC- 7 Valve Core Remover

REMOVAL

1. Discharge refrigerant system using an approved refrigerant recovery system.
2. Remove valve core using Valve Core Remover SA9149AC-7.

INSTALLATION

1. Install and tighten valve core with tool number SA9149AC-7.
2. Evacuate, charge, and leak test A/C system.

NOTE:  To prevent loss of refrigerant charge, make sure to install and tighten cap. Replace cap if seal is missing or damaged.

Service Port Valves|Page 10152 > < Service Port Valves