L Series V6-3.0L VIN R (2004)
![background image](/saturn/l_series/v6-3.0l_vin_r/Page-1556001.png)
Hose/Line HVAC: Service and Repair
Suction Pipe Replacement
SUCTION PIPE REPLACEMENT
TOOLS REQUIRED
-
J 43600 ACR 2000 Air Conditioning Service Center
-
J 39400-A Halogen Leak Detector
REMOVAL PROCEDURE
1. Disconnect the negative battery cable.
2. Recover the refrigerant. Refer to Refrigerant Recovery and Recharging.
3. Remove the bolt that secures the suction pipe to the compressor.
CAUTION: Do not remove hoses or lines before system is fully discharged. System may be under pressure and contact with R134a may
cause personal injury.
4. Remove the suction pipe and seal washer from the compressor.
5. Install the caps on the pipe and compressor to prevent moisture entry and oil spillage.