12. Remove liquid line to condenser cap and plug and install new seal washer.
13. Install liquid line to condenser block and hand start bolt.

Torque:
Liquid Line-to-Condenser Block Bolt: 20 N.m (15 ft-lbs)

14. Install liquid line clamps onto condenser studs and install fasteners.

Torque:
Suction/Liquid Line Assembly Clamps: 5 N.m (44 in-lbs)

15. Install radiator-to-condenser gasket.

Condenser HVAC|Specifications|Page 7668 > < Condenser HVAC|Specifications|Page 7666