saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Mechanical Specifications|Page 11334 > < Mechanical Specifications|Page 11332
Page 10
background image

Torque: 1 N.m (9 in-lbs)

19. Install blower motor assembly into module housing. Fan motor assembly rib must be located into channel in module housing.
20. Connect blower motor electrical connector.
21. Install blower motor housing. Housing rib must fit into slot in module case. Snap left and right clip into place and install fan housing to module

screws.

Torque: 1 N.m (9 in-lbs)

NOTE:  A new filter housing seal must be used whenever the filter housing is removed to prevent water from leaking into module.

22. Remove filter housing seal using a small flat blade screwdriver.
23. Install new filter housing seal.

Mechanical Specifications|Page 11334 > < Mechanical Specifications|Page 11332