saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 13910 > < Initial Inspection and Diagnostic Overview|Page 13908
Page 3
background image

‹› If greater than the specified range, test the ground circuit for an open/high resistance.

7. Connect the harness connector at the horn.
8. Connect a 10A fused jumper wire between the relay switch B+ circuit and the relay controlled output circuit. Verify the horn is activated.

‹› If the horn does not activate, test the relay controlled output circuit for an open/high resistance. If the circuit tests normal, test or replace the

horn.

9. Connect a test lamp between the relay coil B+ circuit and the relay coil control circuit.

10. Press and release the steering wheel horn pad. The test lamp should turn ON and OFF when changing between the commanded states.

‹› If the test lamp is always ON, test the relay coil control circuit for a short to ground. If the circuit tests normal, inspect for a sticking horn

switch.

‹› If the test lamp is always OFF, test the relay coil control circuit for a short to voltage or an open/high resistance. If the circuit tests normal,

inspect for an open horn switch.

11. If all circuits test normal, test or replace the HORN relay.

Horn - Poor Tone

1. Ignition OFF, disconnect the harness connector at the horn.
2. Test for less than 1.0 ohm between the horn ground circuit terminal A and ground.

‹› If greater than the specified range, test the ground circuit for a high resistance.

3. Disconnect the harness connector X3 at the underhood fuse block.
4. Test for less than 1.0 ohm between the control circuit terminal 4 at the underhood fuse block and the control circuit terminal B at the horn

assembly.

‹› If greater than the specified range, test the control circuit for a high resistance.

5. If all circuits test normal, test or replace the horn.

Horn Circuit Test

1. Ignition OFF, disconnect the HORN relay.
2. Connect a test lamp between the relay coil B+ circuit and the relay coil control circuit.
3. Ignition ON, command the horn ON and OFF with a scan tool. The test lamp should turn ON and OFF when changing between the commanded

states.

‹› If the test lamp is always ON, test the control circuit for a short to ground. If the circuit tests normal, replace the BCM.
‹› If the test lamp is always OFF, test the control circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the

BCM.

Component Testing

Horn

1. Ignition OFF, disconnect the harness connector at the horn.
2. Install a 10A fused jumper wire between the control circuit terminal B and 12 volts. Install a jumper wire between the ground circuit terminal A

and ground. Verify the horn emits a clear and even tone.

‹› If the sound emitted is not clear and even, replace the horn assembly.

Relay Test

1. Ignition OFF, disconnect the HORN relay.
2. Test for 60-180 ohms between terminals 85 and 86.

‹› If the resistance is not within the specified range, replace the relay.

3. Test for infinite resistance between the following terminals:

*

30 and 86

*

30 and 87

*

30 and 85

*

85 and 87

‹› If not the specified value, replace the relay.

Initial Inspection and Diagnostic Overview|Page 13910 > < Initial Inspection and Diagnostic Overview|Page 13908