saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

A/C - Odors at Vehicle Start Up|Page 8051 > < A/C - Odors at Vehicle Start Up|Page 8049
Page 16
background image

IMPORTANT:

High-blower relay kit is not included with delayed blower motor control module.

17.

Install high-blower relay kit (P/N 12167634) as follows:

17.1 At terminal D4 of IPJB black 68-way connector, locate PPL wire (circuit 65-blower motor), and cut wire 51 mm (2 in.) from 68-way

connector.

17.2 Splice PPL wire from high-blower relay to length of PPL wire (circuit 65) that goes to I/P harness.

17.3 Splice ORN wire from high-blower relay to length of PPL wire (circuit 65) that goes to IPJB 68-way connector.

17.4 At terminal A10 of IPJB black 68-way connector, splice RED wire from high-blower relay into RED wire (circuit 302-power convenience

feed) from 68-way connector.

17.5 Splice ORN/BLK wire from high-blower relay to BLK/ORN wire from delayed blower motor control module.

18.

Attach ring terminal lead kit (P/N 12112245) to BLK/WHT wire from delayed blower motor control module and BLK/WHT wire from
high-blower relay. Crimp both BLK/WHT wires together before attaching ring terminal lead kit.

19.

Attach ring terminal on the BLK/WHT wires from delayed blower motor control module and high-blower relay to ground location at H-brace.
Make sure that new ring terminal is on top of existing ring terminal.

Torque:

Ring Terminal-to-Ground: 2.2 N.m (20 in-lbs)

A/C - Odors at Vehicle Start Up|Page 8051 > < A/C - Odors at Vehicle Start Up|Page 8049