Control Assembly: Adjustments

NOTICE: Adjust cables by holding cable housing and turning cable housing end.

MODE LEVER

^

If mode lever bounces back on defrost (right) side, shorten cable housing.

^

If mode lever bounces back on I/P outlet (left) side, lengthen cable housing.

TEMPERATURE CABLE

^

If temperature lever bounces back on hot (right) side, lengthen cable housing.

^

If temperature lever bounces back on cold (left) side, shorten cable housing.