Manifold Pressure/Vacuum Sensor: Diagnostic Aids

Pull-to-Seat Connectors

Terminal Removal

IMPORTANT: Pull-to-seat connectors repair kits are available through Saturn Service Parts. The repair kits include the connector with terminals
attached to a short length of wire and crimp and seal splices. Use these kits if the pull-to-seat connector needs replacement.

1. Remove any terminal position assurance (TPA) device.
2. Grasp the lead and pull the terminal to the forward most position. Hold the lead in this stop position.
3. Insert the lock release tool into the front of the terminal cavity. A safety pin may be used for the small Metri-pack 150 series pull-to-seat terminal.
4. Depress the lock tang to unseat the terminal. Never use force to remove a terminal from a connector.
5. Push the wire and the terminal out of the connector cavity.

Cut Lead Installation

1. Insert the wire through the connector and seat the terminal in the connector. Check to make sure the lock tab is engaged.
2. Remove insulation from the end of the cut lead and the harness. Recommended strip length is 9.5 mm (3/8 in.). Caution must be used to prevent

cutting the wire strands.