saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Dome Lamp/Security System - Stays ON/Will Not Arm|Page 3172 > < Engine - Lack of Power/DTC P0326 Set|Page 3166
Page 1
background image

Door Switch: All Technical Service Bulletins
Dome Lamp/Security System - Stays ON/Will Not Arm

BULLETIN NO.: 97-T-34

ISSUE DATE: August, 1997

GROUP/SEQ. NO.: Electrical-08

CORPORATION NO.: 788109

SUBJECT: 

Dome Lamp On at All Times or Intermittently with Dome Lamp Switch in Door Position and/or Intermittent Activation of Security System and/or
Security System will not Arm During Cold Soak (Replace Front Door Jamb Switch[es])

MODELS AFFECTED: 

1996 Saturn Sedans and Wagons, and 1997 Saturn Sedans, Wagons and Coupes built before and including VIN VZ380187

CONDITION: 

During periods of precipitation or periods immediately following precipitation such as rain, a car wash, etc. the dome lamp may come On intermittently
or stay On without any switch input. If the Saturn security system is in the "armed" state and the dome lamp comes On, the dome lamp may trigger a "full
alarm cycle." If the dome lamp is On, the security system will not arm.

CAUSE: 

The condition may be caused by moisture intrusion into the door jamb switch contact cavity. This may create a resistive short circuit between the open
switch contacts, causing the dome lamp to come On.

IMPORTANT: 

Since the rear door jamb switches are mounted facing rearward, they are not as susceptible to moisture intrusion as the front door jamb switches.
When diagnosing this condition, perform the diagnostics on the front door jamb switches only.

CORRECTION: 

Refer to the following procedures to check resistance of door jamb switches

PROCEDURES

NOTICE: 

when removing door jamb switch, make sure not to chafe wires when pulling door jamb switch out of pillar.

1.

Using a pair of pliers, carefully remove door jamb switch by pulling back on the door jamb switch while rocking the door jamb switch side-to-side
and disconnect harness.

2.

Using the Saturn connector test adapter kit (J35616), and the appropriate leads, connect a DVOM to the door jamb switch terminals.

Dome Lamp/Security System - Stays ON/Will Not Arm|Page 3172 > < Engine - Lack of Power/DTC P0326 Set|Page 3166