saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Sunroof - Will Not Open or Close, May Be Intermittant|Page 5690 > < Sunroof - Will Not Open or Close, May Be Intermittant
Page 2
background image

4.

Remove one screw on left side of roof console. Pull down on roof console and disengage roof console from left locator pin allowing roof console
to hang down.

5.

With ignition switch in the ACC, ON or RUN position, check for battery voltage at pin A of the sunroof module connector (black two-way in-line
connector).

6.

If there is battery voltage to pin A of the sunroof module connector and the sunroof is not mechanically binding, refer to the next step and replace
the sunroof switch.

If battery voltage is not present at pin A of sunroof module connector, refer to "Sunroof/Map Light" in the "Power Distribution" section of the
"Electrical Service Manual" for diagnosis procedures. Use the electrical schematics on the last three pages of this bulletin for the diagnosis of the
sunroof electrical system.

7.

Disconnect wiring connector to sunroof switch, depress tabs on switch at roof console and remove sunroof switch from roof console.

8.

Remove sunroof switch and install a new sunroof switch (P/N 21022974-Gray, P/N 21022975-Lt. Biscuit).

9.

Connect wiring connector to sunroof switch.

10.

Install roof console, bezel assembly and map lamp lens.

11.

On Coupes, position sunroof opening trim finish lace back over roof console.

Sunroof Closing

Coupes

1.

With the roof console hanging down (refer to steps 1 through 4 of "Sunroof Switch" procedure in this bulletin), disconnect sunroof switch.

2.

Connect a fused jumper between cavities "C" and "E" of sunroof switch connector to power sunroof closed.

IMPORTANT: 

The gray terminal adapters, from the connector test adapter kit SA9206Z, can be used in making the required fused jumper.

Sedans

1.

With the roof console hanging down (refer to steps 1 through 4 of "Sunroof Switch" procedure in this bulletin), disconnect sunroof switch.

2.

Connect a fused jumper between cavities "C" and "E" of sunroof switch connector.

3.

Connect a fused jumper between cavities "A" and "D" of sunroof switch connector to power sunroof closed.

IMPORTANT: 

Use care not to damage the female terminals in the sunroof switch connector. The gray terminal adapters, from the connector test adapter kit
SA9206Z, can be used in making the required fused jumpers. However, there are only three male adapters in a kit so an additional male adapter will
be required. The following Saturn Lead Kits can be used as male adapters: 12112313, 12112312, 12116709, and 12112432.

Sunroof - Will Not Open or Close, May Be Intermittant|Page 5690 > < Sunroof - Will Not Open or Close, May Be Intermittant