NOTICE: Check the accuracy of the multimeter first by touching the leads together. The meter should read less than 0.10 ohm with the leads touching.

Place the multimeter on the lowest ohmmeter scale. The meter should read less than one ohm, If the meter reads more than one ohm, check the
connections to the ground splice pack (if applicable) or check the ground attachment point. Attach a jumper wire from the ground attachment ring
terminal. Attach it to the ring terminal without moving or disturbing the terminal fastener. This can be done by attaching the jumper wire to the crimp
lead part of the ring terminal. Attach the other end of the jumper wire to a known good ground and watch the multimeter to see if the reading goes below 
one ohm. If the reading goes below one ohm, remove the ground screw or nut, clean the connection surfaces and install, If the reading stays above one
ohm, check for an open in the ground wire. Also check for continuity from the component to the diagnostic service probe.

Other uses for the diagnostic service probe:

^

Compare voltage readings across connectors, components, or lengths of wire. This allows you to observe the operation of a circuit without the
addition of jumper wires or back-probing connections. The best time to diagnose most circuits is while they are operating.

^

Observe changing voltages and compare them to what the PCM is reporting. This can be done by comparing the voltage readings of the PCM
inputs to the reported PCM readings displayed on the portable diagnostic tool (PDT) or the Service Stall System (SSS). This can help detect
damaged or faulty PCM connections, or a faulty PCM.

IMPORTANT: There are differences between the actual voltages from the sensors and the reported voltages by the PCM. This is due to the internal
conversion of these voltages to binary data by the PCM. However, the voltages should generally vary together and the difference should be less than 0.2
volt
.

^

The diagnostic service probe can be used with future test equipment to gain access to a circuit for testing or calibration.

^

The diagnostic service probe can be used to give a good ground access point. Attach a diagnostic service probe to a ground circuit and insert the
multimeter lead in the probe at a ground reference. Check the ground circuit to verify the ground path is good.

Installation

1. Place the cable into the V-slot of the terminal.
2. Press the cable into the V-slot by hand and initiate closing the cover.