Diagram Information and Instructions|Page 6330 > < Diagram Information and Instructions|Page 6328
Page 2
background image

3. Determine proper sleeve for gage wire from the above chart.
4. Position stripped ends in sleeve until wires hit the top in the center of the splice.
5. Hand crimp using the approved crimping tool. Gently tug on wires to make sure they are secure before applying heat to them.

CAUTION: Do not use match or open flame to apply heat to seal.

6. Apply heat using Ultratorch or some other device, heating to 175 °C (347 °F) until glue flows around edges of sleeve.

IMPORTANT: The salmon splice can be used on the 0.35(22 gage) wire if the following additional steps are taken:

7. Remove 19 mm (3/4 in.) of insulation.
8. Bend the stripped portion in half to double the thickness.
9. Twist the stripped, doubled wire and insert into the splice sleeve.

Push-to-Seat Connectors

IMPORTANT: Cut leads with terminals are available from Saturn Service Parts for terminal replacement.

Terminal Removal

1. Remove any terminal position assurance (TPA) locks.
2. Insert the terminal lock release tool into the front of the connector cavity. Pull the wires and terminal out of the back of the connector.

Cut Lead Installation

Diagram Information and Instructions|Page 6330 > < Diagram Information and Instructions|Page 6328