9.

Align the actuator pins to the connector plate.

10.

Install the actuator cover.

11.

Install return exhaust diverter.

IMPORTANT

Clean and lubricate all bolts with Saturn Transaxle Fluid. Wipe off excess fluid and install bolts.

12.

Install the actuator cover bolts and finger tighten.

NOTICE

Over-torquing bolts can cause valves to bind.

13.

Torque actuator cover bolts using torque sequence shown.