SW2 L4-1.9L DOHC VIN 7 (1997)
IMPORTANT:
High-blower relay kit is not included with delayed blower motor control module.
17.
Install high-blower relay kit (P/N 12167634) as follows:
17.1 At terminal D4 of IPJB black 68-way connector, locate PPL wire (circuit 65-blower motor), and cut wire 51 mm (2 in.) from 68-way
connector.
17.2 Splice PPL wire from high-blower relay to length of PPL wire (circuit 65) that goes to I/P harness.
17.3 Splice ORN wire from high-blower relay to length of PPL wire (circuit 65) that goes to IPJB 68-way connector.
17.4 At terminal A10 of IPJB black 68-way connector, splice RED wire from high-blower relay into RED wire (circuit 302-power convenience
feed) from 68-way connector.
17.5 Splice ORN/BLK wire from high-blower relay to BLK/ORN wire from delayed blower motor control module.
18.
Attach ring terminal lead kit (P/N 12112245) to BLK/WHT wire from delayed blower motor control module and BLK/WHT wire from
high-blower relay. Crimp both BLK/WHT wires together before attaching ring terminal lead kit.
19.
Attach ring terminal on the BLK/WHT wires from delayed blower motor control module and high-blower relay to ground location at H-brace.
Make sure that new ring terminal is on top of existing ring terminal.
Torque:
Ring Terminal-to-Ground: 2.2 N.m (20 in-lbs)