saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

A/C - Poor Cooling in High Humidity Conditions|Page 1677 > < A/C - Poor Cooling in High Humidity Conditions
Page 2
background image

Parts Information

Claim Information:

To receive credit for this repair during the warranty coverage period, submit a claim through the Saturn Dealer System for D3082 (Compressor discharge
hose and/or line replace)

Disclaimer

Procedure

1.

Verify customer comment by performing HVAC Performance Test in the HVAC section of the 2002-2003 Saturn VUE Service Manual. If system
performance indicates a low refrigerant charge, go to the next step. If performance test does not indicate a low system charge, review Diagnostic
Charts in the HVAC section of the 2002-2003 Saturn VUE Service Manual to repair/eliminate condition associated with customer's comment.

2.

Raise vehicle on hoist.

3.

Using service tool Black Light J42220 with specially tinted goggles, inspect PRV for leakage. (PRV is located on the A/C hose manifold on the
side of the AC compressor.) The PRV has a paper seal installed on the bottom over the opening. If the PRV has vented, one of the following
conditions will be observed:

^

The seal will glow

^

The seal will be torn

^

The seal will be missing

A/C - Poor Cooling in High Humidity Conditions|Page 1677 > < A/C - Poor Cooling in High Humidity Conditions