saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Oil Pressure Sensor > < Manifold Pressure/Vacuum Sensor|Locations|Page 3282
Page 1
background image

Manifold Pressure/Vacuum Sensor: Service and Repair

MANIFOLD ABSOLUTE PRESSURE (MAP) SENSOR

REMOVAL

1. Disconnect intake air temperature (IAT) sensor connector.
2. Loosen clamp at air cleaner assembly.
3. Remove push pin attachment from outlet resonator/duct assembly to support bracket.
4. Loosen clamp at throttle body assembly.
5. Disconnect PCV fresh air vent hose at cam cover.
6. Remove outlet resonator/duct assembly.
7. Disconnect MAP sensor electrical connector.
8. Remove MAP sensor and the MAP sensor port seal if it is still retained in the intake manifold.

INSTALLATION

1. Install MAP sensor with port seal into intake manifold.
2. Connect MAP sensor electrical connector. Push in connector until a click is heard and pull back to confirm a positive engagement.
3. Install outlet resonator/duct assembly into position.
4. Connect PCV fresh air vent hose assembly.
5. Tighten clamp at throttle body assembly.
6. Position outlet resonator/duct assembly up with support bracket and install push pin.
7. Tighten clamp at air cleaner assembly.
8. Connect intake air temperature (IAT) sensor connector.

Oil Pressure Sensor > < Manifold Pressure/Vacuum Sensor|Locations|Page 3282