saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Scan Tool Does Not Communicate with Class 2 Device|Page 5755 > < Technician Safety Information|Page 5752
Page 1
background image

Information Bus: Testing and Inspection
Scan Tool Does Not Communicate with Class 2 Device

Scan Tool Does Not Communicate with Class 2 Device

Circuit Description

Modules connected to the class 2 serial data circuit monitor for serial data communications during normal vehicle operation. Operating information and
commands are exchanged among the modules. Connecting a scan tool to the data link connector (DLC) allows communication with the modules for
diagnostic purposes.

Diagnostic Aids

The engine will not start when there is a total loss of class 2 serial data communication while the ignition is OFF. The following conditions will cause a
total loss of class 2 serial data communication:

*  A class 2 serial data circuit shorted to ground.
*  A class 2 serial data circuit shorted to voltage.
*  An internal condition within a module or connector on the class 2 serial data circuit, that causes a short to voltage or ground to the class 2 serial

data circuit.

Test Description

Scan Tool Does Not Communicate with Class 2 Device|Page 5755 > < Technician Safety Information|Page 5752