Control Assembly: All Technical Service Bulletins
A/C - Poor Performance/Erratic Operation

File in Section: 01 - HVAC 

Bulletin No.: 03-01-37-003

Issue Date: December, 2003

Subject:
Inoperative HVAC Rear Defrost, Recirc, or Air Condition (AC) Mode switches and/or Reduced or No Airflow from Vents (Calibrate HVAC Module
Controller and/or Inspect C1 HVAC Controller Connector)

Models Affected:
2002-2004 Saturn VUE Vehicles

Attention: Technician

Condition:

Customers may comment that one or both of the following conditions exist:

^

Condition 1 - The HVAC controller rear defrost, recirc, and/or A/C switch is inoperative.

^

Condition 2 - Reduced or no airflow from outlets and/or selected HVAC modes are inoperative when the HVAC blower motor is on.

Cause:

The cause may be one of the following:

^

Cause for Condition 1 - HVAC controller C1 connector is not fully inserted.

^

Cause for Condition 2 - HVAC controller out of calibration or C1 connector is not fully inserted.

Correction:

^

Correction for Condition 1 - Remove control head and ensure the C1 connector is fully inserted.

^ Correction for Condition 2 - Re-calibrate the controller and retest. If concern is not resolved, remove controller and ensure C1 connector is fully

inserted.

Procedure

Condition 1 - The HVAC controller rear defrost, recirc, and/or A/C switch is inoperative.

To inspect the C1 (20-way black) HVAC controller connector, perform the following:

HVAC Controller/Radio Bezel Removal