1. Remove any dirt, grease, or other contaminants from the mounting surface.
2. Connect the SIS electrical connector and insert into the connector position assurance (CPA) to secure.
3. Place the SIS through the access hole in the lock pillar.
4. Slide the module down and locate the captured fastener in the key slots of the lock pillar.

NOTE:  Refer to Fastener Notice in Service Precautions.

Tighten the fastener to 10 N.m (89 lb in).

5. Install the center pillar lower molding.
6. Enable the SIR system. Refer to SIR Disabling and Enabling Zone 2 or to SIR Disabling and Enabling Zone 6.