saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Drive Motor Power Cable|Service and Repair|Page 4504 > < Drive Motor Power Cable|Service and Repair|Page 4502
Page 15
background image

11. Place a NEW terminal block seal onto the generator control module.
12. Unsecure, position and install the 36-volt terminal block to the generator control module.
13. Install the 36-volt terminal block nuts (1) to the generator control module.

Tighten the nuts to 10 N.m (89 lb in).

14. Install the 36-volt positive battery cable nut (2) to the generator control module.

Tighten the nut to 10 N.m (89 lb in).

15. Install the 12-volt positive battery cable nut (5) from the generator control module.

Tighten the nut to 10 N.m (89 lb in).

16. Install the generator control module 3-phase cable nuts at the generator control module.

Tighten the nuts to 8 N.m (71 lb in).

Drive Motor Power Cable|Service and Repair|Page 4504 > < Drive Motor Power Cable|Service and Repair|Page 4502