VUE FWD L4-2.4L Hybrid (2007)
4. Disconnect the 2 engine wiring harness electrical connectors (1) from the generator control module.
5. WAIT at least 5 minutes in order to allow the voltage stored in the generator control module to discharge.
6. Remove the generator control module cover bolts and cover.
7. The generator control module will have to be checked for voltage potential using a voltmeter. First, verify that the voltmeter works:
1. Set the voltmeter to DC voltage.
2. Measure the vehicle's 12-volt battery voltage.
3. The meter should read greater than +12 volts DC.
8. Now, check the generator control module for voltage potential, in order to ensure that the module has been disabled.
1. Measure from the 36-volt positive terminal (3) to vehicle chassis ground (2). The voltage should be less than 3 volts.
2. Measure from the 12-volt positive terminal (5) to vehicle chassis ground (2). The voltage should be less than 3 volts.
3. Measure from the negative terminal (4) to vehicle chassis ground (2). The voltage should be less than 3 volts.