Important:  Never assume the battery pack is disabled when the generator battery disconnect control module cover is opened.

10. The generator battery will have to be checked for voltage potential using a voltmeter first, verify that the voltmeter works:

1. Set the voltmeter to DC voltage.
2. Measure the vehicle's 12-volt battery voltage (at 12-volt positive jumper location and negative battery cable).
3. The meter should read greater than +12 volts DC.

11. Now, check the generator battery for voltage potential in order to ensure that the generator battery has been disabled.

1. Measure from the positive (3) stud to the negative stud (2). The voltage should be less than 3 volts.
2. Measure from the positive (3) stud to vehicle chassis ground (1). The voltage should be less than 3 volts.
3. Measure from the negative (2) stud to vehicle chassis ground (1). The voltage should be less than 3 volts.
4. After verifying that there is no voltage present, the 36-volt negative and positive battery cables can now be removed from the generator

battery.

12. Remove the plastic nut (1) from the 36-volt negative battery cable lead.