4. Disconnect the master cylinder fluid level sensor electrical connector (1).
5. Disconnect the master cylinder primary brake pipe fitting (2).

Cap the brake pipe fitting and plug the master cylinder outlet port to prevent brake fluid loss and contamination.

6. Disconnect the master cylinder secondary brake pipe fitting (3).

Cap the brake pipe fitting and plug the master cylinder outlet port to prevent brake fluid loss and contamination.

7. Remove the 2 master cylinder nuts (1).
8. Remove the master cylinder (2).

Installation Procedure

1. If installing a new master cylinder, bench bleed the master cylinder. Refer to Master Cylinder Bench Bleeding  (See: Procedures/Master Cylinder

Bench Bleeding) .