VUE FWD V6-3.5L (2008)
Tighten the sensor to 42 N.m (31 lb ft) .
3. Connect the engine wiring harness electrical connector (3) to the HO2S electrical connector (2).
4. Install the CPA retainer.
5. Install the HO2S electrical connector rosebud clip to the engine wiring harness retaining strap (6).
6. Remove the air cleaner outlet duct. Refer to Air Cleaner Outlet Duct Replacement (See: Fuel Delivery and Air Induction/Air Cleaner Housing/Air
Cleaner Fresh Air Duct/Hose/Service and Repair/Air Cleaner Outlet Duct Replacement) .