scion Workshop Repair Guides

Scion Workshop Service and Repair Manuals

Radiator Cooling Fan Motor|Locations|Page 1593 > < Radiator Cooling Fan Motor|Locations|Page 1591
Page 2
background image

c. Check that the cooling fan rotates.

If not, replace the engine coolant temperature sensor.

3. INSPECT FAN

a. Disconnect the fan connector.
b. Connect the battery and ammeter to the fan connector.
c. Check that the fan rotates smoothly, then check the reading on the ammeter.

Standard amperage: 5.2 to 8.2 A at 20°C (68°F) 
If the amperage is not as specified, replace the cooling fan motor.

d. Reconnect the fan connector.

4. INSPECT NO. 2 FAN

a. Disconnect the No. 2 fan connector.
b. Connect the battery and ammeter to the No. 2 fan connector.
c. Check that the No .2 fan rotates smoothly, then check the reading on the ammeter.

Standard amperage: 5.2 to 8.2 A at 20°C (68°F) 
If the amperage is not as specified, replace the cooling fan motor.

d. Reconnect the No. 2 fan connector.

INSPECTION 

Radiator Cooling Fan Motor|Locations|Page 1593 > < Radiator Cooling Fan Motor|Locations|Page 1591