tC L4-2.4L (2AZ-FE) (2005)
Canister Purge Control Valve: Testing and Inspection
INSPECT VACUUM SWITCHING VALVE ASSEMBLY NO.1
a. Check the resistance.
1. Using an ohmmeter, measure the resistance between the terminals.
If the resistance is not as specified, replace the vacuum switching valve No. 1.
b. Check the vacuum switching valve No. 1 for ground.
1. Using an ohmmeter, check the resistance between each terminal and the body.
If the resistance is not as specified, replace the vacuum switching valve No. 1.
c. Check the operation.
1. Check that air does not flow from port E to port F.
If the operation is not as specified, replace the vacuum switching valve No. 1.